UL1723 FEP wire, Fluorinated Ethylene Propylene insulated, is a type of wire that is known for its exceptional thermal and electrical properties. Its insulation is a fluoropolymer resin that combines the best characteristics of fluorocarbons and hydrocarbons. This contributes to a quality FEP wire that is not only resistant to high temperature but also has excellent dielectric strength, making it ideal for a wide range of applications.

Category: Tag:

Description

UL Style Number: UL1723 FEP Insulation Thickness: 0.23mm

Conductor 32AWG ~ 10AWG.
Tinned stranded or solid copper conductor, or Silver plated copper, Nickel plated copper.
Insulation: FEP fluoroplastic, optional color schemes as black, white, grey, red, blue, yellow, green, brown, etc.
Rated temperature: 200℃, rated voltage: TBD.
Uniform insulation thickness for easy process of stripping and cutting.
UL VW-1 and CUL FT1 vertical flame resistant test verified.
Ordinary strands tinned, and over coated conductors available.

Application: Widely used for home appliance, headlamp, industrial machine, electronic thermal products, etc.

Specification

Conductor Insulation Thickness Overall Diameter Standard Package Conductor Resistance
AWG No/mm mm mm feet/reel meter/reel Ω/km (at 20℃)
32 1/0.20 0.23 0.75 4000 1220 588.00
7/0.08 0.23 0.75
30 1/0.254 0.23 0.80 2000 610 381.00
7/0.10 0.23 0.80
28 1/0.32 0.23 0.85 2000 610 239.00
7/0.127 0.23 0.85
26 1/0.404 0.23 0.95 2000 610 150.00
7/0.16 0.23 1.00
19/0.10 0.23 1.00
24 1/0.50 0.23 1.05 2000 610 94.20
7/0.20 0.23 1.15
19/0.12 0.23 1.15
22 1/0.643 0.23 1.20 2000 610 59.40
7/0.254 0.23 1.30
19/0.15 0.23 1.30
20 1/0.813 0.23 1.30 2000 610 36.70
7/0.32 0.23 1.50
19/0.19 0.23 1.50
18 1/1.02 0.23 1.58 2000 610 23.20
7/0.39 0.23 1.75
19/0.235 0.23 1.75
16 1/1.32 0.23 1.85 2000 610 14.60
7/0.49 0.23 2.07
19/0.30 0.23 2.07
14 19/0.37 0.23 2.46 1000 305 8.96
12 19/0.47 0.23 3.00 1000 305 5.64
10 19/0.61 0.23 3.70 1000 305 3.55
Author